Great service! 2nd Capicitator and they aren’t cheap. But repaired fast and great job!
Justin always does a great job very friendly and respectful.
Hunter is by far the best technician we have had to date. Amazing work
Technician arrived promptly and looked at the water heater. He made a few estimates for various services and emailed them to me for review. Although I ended up using a different company, I will keep them in mind for any future plumbing projects.
Hunter is the best, very communicative with the customer and thorough with his job.
Very courteous, explained things very well both visually and verbally. Made sure all that was explained was understood. Extremely patient.
Mark has been here several times. He is pleasant and skillful in diagnosing and doing the service.
Mark Dennison took his time to check all of the A/C unit. Very friendly and knowledgeable technician. Really appreciate his work and attitude.
Mark is very thorough and pleasant. Explains everything well.
Ian was upfront on the cost and did a great job replacing toilet.
Performed tune up on a Lennox heat at pump with air handler installednin 2011. Compressor is amping high, condenser fan motor is acceptable. Blower wheel is dirty and should be cleaned. UV system is acceptable. Customer states that there is uneven air flow and the bedroom is very warm. Static pressure is acceptable. Could not determine reason for uneven airflow. Outdoor unit was good washed and waxed.
Completed tuneup on a nine year-old heat pump checked both indoor and outdoor systems washed outdoor condenser out checked pressures checked amp readings and everything was within a manufacture. Specs on the indoor unit checked both filters checked coil checked drain line and checked blower motor. Everything is camping well within manufacture specs checked The function of the float switch and it shut system off the system is working as designed at time of tuneup.
Upon arrival Airhandler was on and blowing while outdoor was not. During evaluation found that the dual run cap had failed, replaced cap and ran system check. Found no other issues at this time left with system cooling
Arrived to no cool. 06 "open start circuit" code present on the heat pump circuit board. 35/5 auxiliary motor start reading as 55/5. Replaced auxiliary motor start under parts only warranty. Performed function check. System running and cooling the home upon departure.
2010 Payne Airhandler Checked and tightened all electrical connections Drain was clear but did not have a P trap so the drain only drains when system is off Blower motor and wheel have Biological growth and dust build up Evaporator coil has dust, dirt and biological growth build up Supply plenum has biological growth and dust build up System has no drain protection 2010 Payne Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed the condenser coils from the inside out Waxed the top of the unit Recommended Level 2 Duct cleaning, UV system for biological growth, building P trap for the drain, drain protection and compressor saver. Customer declined all work at this time
We will replace Frost free on back of home. If wall access is needed extra charges will apply
No show at this time
Found capacitor completely dead. Replaced and verified system was cooling house was 91 degrees when I left system is over 20 years I recommend replacing system . Customer declined.
Upon arrival talk to homeowner about issues with system checked all electrical components check refrigerant pressures and everything is looking good upon inspection of drain line found p-trap full of gunk went ahead cleaned out the p-trap and treated condensation pan also fixed drain line outside and added a 90 to the end of it and verified proper condensate drainment. Also found insulation on suction line on the outdoor system needs to be rewrapped
2019 Amana Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain has slight build up in trap Uv system is functional Blower motor and wheel were acceptable Evaporator coil was acceptable 2019 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from bottom of the unit Washed condenser coils from inside out Waxed top of the unit Recommended UV system upgrade along with clearing and treatment of the drain
6/19/25 I will be back tomorrow to perform a diagnostic at 1:00 currently the attic access is not available so they need time to move things around
For this job I performed a complimentary plumbing inspection, I provided the customer with an estimate to replace all his angle stops.
Upon technicians arrival technician found that the unit was clogged technician cleared and treated drain
Gave customer quote on generator