Hunter is by far the best technician we have had to date. Amazing work
Technician arrived promptly and looked at the water heater. He made a few estimates for various services and emailed them to me for review. Although I ended up using a different company, I will keep them in mind for any future plumbing projects.
Hunter is the best, very communicative with the customer and thorough with his job.
Very courteous, explained things very well both visually and verbally. Made sure all that was explained was understood. Extremely patient.
Mark has been here several times. He is pleasant and skillful in diagnosing and doing the service.
Mark Dennison took his time to check all of the A/C unit. Very friendly and knowledgeable technician. Really appreciate his work and attitude.
Mark is very thorough and pleasant. Explains everything well.
Ian was upfront on the cost and did a great job replacing toilet.
Derek was able to fix the problem with excellent results. Enjoyed his company also.
The men were patient and explained everything go on. They were here on time and very professional.
Upon technicians arrival technician found that the unit was clogged technician cleared and treated drain
Gave customer quote on generator
Wet switch was tripped up on arrival. Found no moisture under the system or even the cardboard that the wet switch was sitting on. Tested drain with a gallon of water and had no issues. Replaced faulty wet switch under warranty and left with system in cool
Arrived to no cool. Failed 45/7.5 capacitor was preventing the system from starting up. Replaced capacitor under P&L warranty. System running and cooling the home upon departure.
2008 2.5t r410a hp closet upflow. Expired manufacturer warranty. Sediments in drain line. Biological growth present inside indoor unit. Evaporator coil has detected refrigerant molecules entering into breathable air, oils stains and rust present. Blower wheel is heavy with buildup. Compressor inrush amperage exceeds manufacturer specifications. History of capacitor replacements. Refrigerant charge is below manufacturer specifications confirming evaporator coil inspection issues. Homeowner was over my shoulder at all times and wanted me perform all of my duties. Once the information became apparent I offered solutions that expressed system age, parts availability, warranty etc... but were declined. I explained that because we did not come to a viable solution for him that the decline work tab is to protect all parties in the event that we are called out again within 45 days and that a service fee will be applied. Left on good terms, homeowner was pleased with my information just not
Gave estimates for Halo and wh customer is collecting estimates and will get bk with us
Upon arrival customer stated almost a year ago he had a friend work on his system. The friend changed out the Airhandler coil with a stand alone coil. Talked with customer about getting correct coil. Talked with Rob to find pricing and availability. Per Mark W Rob will get in touch with him. Pausing job for now.
Upon arrival techtbtalked to home owner to see what was going on tech found Is that two other companies have been out and given estimates for float switch tech talked to homeowner and installed float switch tech made sure system was running properly before leaving
Upon arrival tech removed the old supply plinam and installed the new one the unit is runing
Upon arrival tech started with the air handler tech found that the insulation inside the supply plenum is falling apart tech recommends replacing the plenum tech headed out side where tech found everything to be working properly and up to standards. The home owner is going through financing Tech will need to return once metal plenum comes in to install it properly. Air handler dimension 24" × 12"× 4FT
Customer interested in filtration/softener and possible ro system at kitchen sink. Need to get info/ literature and follow up with customer. Customer did not want inspection
Fully functional. Happy homeowner. Answered all questions, insulated the primary condensate line per code and adjusted door of condenser unit to seat properly. Will talk to install about the possibility of adding rubber gromets to the bolts on the frame to the brick. Low voltage is not protected.
Install 60k hz inverter heat pump with ultra high efficiency filtration with uv system, code kit and duct cleaning
Came to job for complimentary inspection and guy had a few things he wanted quotes on and gave him those quotes and also talked about adding a generator plug And was very interested in that and will probably call us back in the future.Just has the big system being put in same day and just needs sometime before he does it